Diagnostic Accuracy of a Novel Tuberculosis Point-of-Care Urine Lipoarabinomannan Assay for People Living with HIV: A Meta-Analysis of Individual In- and Outpatient Data

Tobias Broger, Mark P. Nicol, Rita Székely, Stephanie Bjerrum, Bianca Sossen, Charlotte Schutz, Japheth A. Opintan, Isik S. Johansen, Satoshi Mitarai, Kinuyo Chikamatsu, Andrew D. Kerkhoff, Aurélien Macé, Stefano Ongarello, Graeme Meintjes, Claudia M. Denkinger, Samuel G. Schumacher*

*Corresponding author for this work

Research output: Chapter in Book/Report/Conference proceedingBook chapterResearchpeer-review

Abstract

Traditional diagnostic methods, such as culture or smear microscopy, are slow or low in sensitivity. More sensitive modern techniques, such as Xpert MTB/RIF, require a certain infrastructure, are costly, and are not widely accessible. Diagnostic accuracy was determined separately for each cohort, and 95% confidence intervals were computed using Wilson’s score method. Sensitivity and specificity of LF-LAM and SILVAMP-LAM for each cohort were compared using the McNemar test. The inclusion of different cohorts with different study designs resulted in heterogeneity and different exclusion rates; however, differences in diagnostic sensitivity between SILVAMP-LAM and LF-LAM persisted in a sensitivity analysis including the “unclassifiable” category and in the analyses by CD4 subgroup. Further, antiretroviral treatment may have influenced patient outcome and thus the reference standard categories “possible TB” and “unclassifiable”. Limited budgets, lack of country-specific data, administrative hurdles such as local regulatory approval, lack of coordination between national TB and HIV programs, and small perceived patient population size.

Original languageEnglish
Title of host publicationAdvances in Medical Imaging, Detection, and Diagnosis
EditorsRaj Bawa, Gerald F. Audette, S. R. Bawa, Bela Patel, Bruce D. Johnson, Rajeev Khanna
PublisherJenny Stanford Publishing
Publication date2023
Pages955-972
ISBN (Print)9789814877466
ISBN (Electronic)9781000602043
DOIs
Publication statusPublished - 2023

Keywords

  • composite reference standard (CRS)
  • cross-reactivity
  • demographics
  • Fujifilm SILVAMP TB LAM (SILVAMP-LAM)
  • individual patient data (IPD)
  • lipoarabinomannan (LAM)
  • microbiological reference standard (MRS)
  • mycobacteria growth indicator tube (MGIT)
  • Mycobacterium tuberculosis (Mtb)
  • nontuberculous mycobacteria (NTM)
  • people living with HIV (PLHIV)
  • point-of-care (POC)
  • tuberculosis (TB)
  • urinary tract
  • Xpert MTB/RIF (Xpert)

Fingerprint

Dive into the research topics of 'Diagnostic Accuracy of a Novel Tuberculosis Point-of-Care Urine Lipoarabinomannan Assay for People Living with HIV: A Meta-Analysis of Individual In- and Outpatient Data'. Together they form a unique fingerprint.

Cite this