TY - JOUR
T1 - Lead complications after cardiac surgery in patients with cardiac implantable electronic devices
AU - Frausing, Maria Hee Jung Park
AU - Nielsen, Jens Cosedis
AU - Johansen, Jens Brock
AU - Jørgensen, Ole Dan
AU - Kristensen, Jens
AU - Olsen, Thomas
AU - Gerdes, Christian
AU - Kronborg, Mads Brix
N1 - Publisher Copyright:
© The Author(s) 2022. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
PY - 2022/7/11
Y1 - 2022/7/11
N2 - OBJECTIVES: Manipulation of the heart during cardiac surgery in patients with cardiac implantable electronic devices (CIEDs) may result in lead damage or displacement, but whether cardiac surgery truly infers an excess risk of lead failure is not known. The objective of this study was to examine the risk of lead complications after cardiac surgery in patients with CIEDs. METHODS: We conducted a nationwide nested case-control study. The source population comprised all Danish patients ≥18 of age who underwent a de novo CIED implantation during 1998-2017. For inclusion, patients had to be alive and event free 6 months after implantation. Cases were matched 1:30 to controls on time, age, sex, and device type using risk set sampling. We used conditional logistic regression to estimate incidence rate ratios (IRRs) for the association between cardiac surgery and lead-related reoperation. RESULTS: Our final population consisted of 67 621 patients. We identified 1437 (2.1%) incident cases of lead-related reoperations and 42 698 controls. Risk of lead complications was highest within 6 months of cardiac surgery [IRR 9.7, 95% confidence interval (CI) 6.3-14.8, adjusted IRR 9.6, 95% CI 6.2-14.7], and at 1 year, the relative risk of lead-related reoperation was close to unity (adjusted IRR 1.2, 95% CI 0.8-1.7). CONCLUSIONS: Cardiac surgery was associated with a considerable risk of lead complications in patients with de novo CIEDs.
AB - OBJECTIVES: Manipulation of the heart during cardiac surgery in patients with cardiac implantable electronic devices (CIEDs) may result in lead damage or displacement, but whether cardiac surgery truly infers an excess risk of lead failure is not known. The objective of this study was to examine the risk of lead complications after cardiac surgery in patients with CIEDs. METHODS: We conducted a nationwide nested case-control study. The source population comprised all Danish patients ≥18 of age who underwent a de novo CIED implantation during 1998-2017. For inclusion, patients had to be alive and event free 6 months after implantation. Cases were matched 1:30 to controls on time, age, sex, and device type using risk set sampling. We used conditional logistic regression to estimate incidence rate ratios (IRRs) for the association between cardiac surgery and lead-related reoperation. RESULTS: Our final population consisted of 67 621 patients. We identified 1437 (2.1%) incident cases of lead-related reoperations and 42 698 controls. Risk of lead complications was highest within 6 months of cardiac surgery [IRR 9.7, 95% confidence interval (CI) 6.3-14.8, adjusted IRR 9.6, 95% CI 6.2-14.7], and at 1 year, the relative risk of lead-related reoperation was close to unity (adjusted IRR 1.2, 95% CI 0.8-1.7). CONCLUSIONS: Cardiac surgery was associated with a considerable risk of lead complications in patients with de novo CIEDs.
KW - Cardiac implantable electronic device
KW - Cardiac surgery
KW - Complications
KW - Coronary artery bypass graft
KW - Heart valve surgery
KW - Implantable cardioverter defibrillator
KW - Pacemaker
U2 - 10.1093/ejcts/ezac318
DO - 10.1093/ejcts/ezac318
M3 - Journal article
C2 - 35639747
AN - SCOPUS:85134855186
SN - 1873-734X
VL - 62
JO - European Journal of Cardio-Thoracic Surgery
JF - European Journal of Cardio-Thoracic Surgery
IS - 2
M1 - ezac318
ER -